8.6
SECTION 8 • REQUIRED INSPECTION, SERVICE & MAIN TE NANCE
290 Sundancer
®
Keep under a trickle charge.
When placing battery back into service, remove
excess grease from terminals, recharge as
necessary and reinstall in boat.
D. HEAD SYSTEM
Flush entire system thoroughly with fresh
water.
Pump out holding tank.
Remove water line from inlet fi tting located
on back bottom half of water valve on head.
Flush one gallon (four liters) antifreeze mixed
with one gallon (four liters) of water through
toilet and let vacuum pump run for one or two
minutes.
Shut FRESH WATER PUMP breaker OFF.
Pump out holding tank.
E. WATER SYSTEM
Turn ON the FRESH WATER PUMP breaker.
Open water faucet, let system drain
completely.
Turn OFF the FRESH WATER PUMP breaker.
Water must be removed from the water lines
with air pressure or fl ushed with a nontoxic
antifreeze.
USING PRESSURIZED AIR TO REMOVE WATER FROM
WATER LINES:
You must have an air compressor with air hose
and air nozzle.
Remove water hoses from water pump.
Alternate opening one faucet at a time to make
sure water is removed from each line.
Blow air through the water lines removed from
the water pump.
NOTE: When blowing air be careful not to blow air
with all faucets closed. System could be damaged
by over pressurization and create water leaks.
Cover hose ends with screen or broad weave
cloth and tape in place to keep out dirt and
bugs.
USING NONTOXIC WINTERIZING ANTIFREEZE:
Purchase a nontoxic winterizing antifreeze for
fresh water systems from a marine or RV supply
retailer.
With all water pumped out of the system add
nontoxic antifreeze to the water tank. Pour
in enough to be pumped to all faucets and
showers.
Close all faucets and turn on water system.
Open one faucet at a time. Close faucet when
nontoxic antifreeze comes out of faucet.
After all faucets and showers have been treated,
open all faucets and pump out remaining
nontoxic antifreeze.
WATER HEATER WINTERIZATION
Refer to your water heater Owner’s Manual for
detailed information on preparing water heater
for storage and winterization.
F. FUEL SYSTEMS
GASOLINE:
Fill fuel tank with gasoline and the recommended
amount of stabilizer and conditioner such as
“Stabil
®
”.
Run engine(s) for ten minutes to ensure that
all gasoline in the carburetor and fuel lines are
treated.